{"product_id":"festes-lungenphantom","title":"Fixed lung phantom","description":"\u003cp data-start=\"110\" data-end=\"716\" class=\"\"\u003eThe \u003cstrong data-start=\"134\" data-end=\"158\"\u003elung tissue phantom\u003c\/strong\u003e replaces human lung tissue and provides a realistic simulation for testing and calibration in medical imaging. Together with the \u003cstrong data-start=\"312\" data-end=\"332\"\u003eR16921\u003c\/strong\u003e and \u003cstrong data-start=\"337\" data-end=\"347\"\u003eR16922\u003c\/strong\u003e phantoms, it replicates complete human body structures. The phantom enables precise testing and calibration of \u003cstrong data-start=\"466\" data-end=\"472\"\u003eCT\u003c\/strong\u003e , \u003cstrong data-start=\"474\" data-end=\"481\"\u003eMRI\u003c\/strong\u003e , and \u003cstrong data-start=\"486\" data-end=\"501\"\u003eultrasound\u003c\/strong\u003e devices that rely on the visualization of lung tissue. It provides a valuable solution for quality control and ensures that imaging systems operate accurately under realistic conditions.\u003c\/p\u003e\n\n\u003cp data-start=\"718\" data-end=\"743\" class=\"\"\u003e \u003cstrong data-start=\"718\" data-end=\"741\"\u003eAreas of application:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"744\" data-end=\"1224\"\u003e\n\n\u003cli data-start=\"744\" data-end=\"855\" class=\"\"\u003e\n\n \u003cp data-start=\"746\" data-end=\"855\" class=\"\"\u003eCalibration and quality control of \u003cstrong data-start=\"786\" data-end=\"792\"\u003eCT\u003c\/strong\u003e , \u003cstrong data-start=\"794\" data-end=\"801\"\u003eMRI\u003c\/strong\u003e and \u003cstrong data-start=\"806\" data-end=\"828\"\u003eultrasound devices\u003c\/strong\u003e for lung imaging \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"856\" data-end=\"990\" class=\"\"\u003e\n\n\u003cp data-start=\"858\" data-end=\"990\" class=\"\"\u003e Simulate human lung tissue together with the \u003cstrong data-start=\"926\" data-end=\"936\"\u003eR16921\u003c\/strong\u003e and \u003cstrong data-start=\"941\" data-end=\"951\"\u003eR16922\u003c\/strong\u003e phantoms for full body structure testing \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"991\" data-end=\"1107\" class=\"\"\u003e\n\n\u003cp data-start=\"993\" data-end=\"1107\" class=\"\"\u003eUse in medical research projects and studies investigating lung structures and diseases \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1108\" data-end=\"1224\" class=\"\"\u003e\n\n\u003cp data-start=\"1110\" data-end=\"1224\" class=\"\"\u003e Training of radiologists and medical professionals in the use of imaging devices that image lung tissue\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1226\" data-end=\"1257\" class=\"\"\u003e \u003cstrong data-start=\"1226\" data-end=\"1255\"\u003eAdvantages at a glance:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"1258\" data-end=\"1994\"\u003e\n\n\u003cli data-start=\"1258\" data-end=\"1370\" class=\"\"\u003e\n\n\u003cp data-start=\"1260\" data-end=\"1370\" class=\"\"\u003e \u003cstrong data-start=\"1260\" data-end=\"1301\"\u003eRealistic lung tissue simulation:\u003c\/strong\u003e Replaces human lung tissue for precise imaging analyses.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1371\" data-end=\"1536\" class=\"\"\u003e\n\n \u003cp data-start=\"1373\" data-end=\"1536\" class=\"\"\u003e\u003cstrong data-start=\"1373\" data-end=\"1392\"\u003eCompatibility:\u003c\/strong\u003e Can be used in combination with the \u003cstrong data-start=\"1421\" data-end=\"1441\"\u003eR16921\u003c\/strong\u003e and \u003cstrong data-start=\"1446\" data-end=\"1456\"\u003eR16922\u003c\/strong\u003e phantoms to simulate complete human body structures. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1537\" data-end=\"1692\" class=\"\"\u003e\n\n\u003cp data-start=\"1539\" data-end=\"1692\" class=\"\"\u003e \u003cstrong data-start=\"1539\" data-end=\"1565\"\u003eVersatile:\u003c\/strong\u003e Suitable for \u003cstrong data-start=\"1579\" data-end=\"1585\"\u003eCT\u003c\/strong\u003e , \u003cstrong data-start=\"1587\" data-end=\"1594\"\u003eMRI\u003c\/strong\u003e and \u003cstrong data-start=\"1599\" data-end=\"1614\"\u003eultrasound\u003c\/strong\u003e to realistically display lung tissue and test imaging systems. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1693\" data-end=\"1844\" class=\"\"\u003e\n\n\u003cp data-start=\"1695\" data-end=\"1844\" class=\"\"\u003e \u003cstrong data-start=\"1695\" data-end=\"1720\"\u003ePrecise Calibration:\u003c\/strong\u003e Enables optimization of image quality and accurate calibration of imaging systems for lung examinations.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1845\" data-end=\"1994\" class=\"\"\u003e\n\n \u003cp data-start=\"1847\" data-end=\"1994\" class=\"\"\u003e\u003cstrong data-start=\"1847\" data-end=\"1881\"\u003eEducation and Training Aid:\u003c\/strong\u003e Provides valuable resources for training radiologists and technicians in lung tissue imaging.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1996\" data-end=\"2024\" class=\"\"\u003e \u003cstrong data-start=\"1996\" data-end=\"2022\"\u003eFurther information:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"2025\" data-end=\"2339\"\u003e\n\n\u003cli data-start=\"2025\" data-end=\"2211\" class=\"\"\u003e\n\n\u003cp data-start=\"2027\" data-end=\"2211\" class=\"\"\u003e The phantom provides an exact replica of lung tissue and complements the R16921 and \u003cstrong data-start=\"2127\" data-end=\"2137\"\u003eR16922\u003c\/strong\u003e \u003cstrong data-start=\"2103\" data-end=\"2122\"\u003ephantoms\u003c\/strong\u003e to enable realistic lung and body structure simulations. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2212\" data-end=\"2339\" class=\"\"\u003e\n\n\u003cp data-start=\"2214\" data-end=\"2339\" class=\"\"\u003e It helps to test, calibrate and optimize imaging systems' performance in visualizing lung tissue.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Erler-Zimmer","offers":[{"title":"300 x 300 x 10mm","offer_id":55385124405513,"sku":"EZR16923A","price":420.14,"currency_code":"GBP","in_stock":true},{"title":"300 x 300 x 20mm","offer_id":55385124438281,"sku":"EZR16923B","price":526.33,"currency_code":"GBP","in_stock":true},{"title":"300 x 300 x 30mm","offer_id":55385124471049,"sku":"EZR16923C","price":630.68,"currency_code":"GBP","in_stock":true},{"title":"300 x 300 x 40mm","offer_id":55385124503817,"sku":"EZR16923D","price":849.44,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0889\/3356\/4681\/files\/Screenshot2025-04-30115618.png?v=1754924529","url":"https:\/\/www.docmed.de\/en-gb\/products\/festes-lungenphantom","provider":"DocMed GmbH","version":"1.0","type":"link"}